The most economic kinematic viscometer for a large variety of samples
SVM 2001 allows for easy and fast viscosity measurements from 15 °C to 100 °C, from fuels and lubes to used oils. Simply fill the sample from a syringe and start the measurement to get the results within a few minutes. Cover the full viscosity range from 0.2 mm²/s to 30 000 mm²/s with one single measurement cell – no need to change capillaries. For easy cleaning and maintenance, the measurement cell is accessible for cleaning without any tools thanks to its patented design.
Viscosity measurement made easy
When testing diverse samples like used oils, finding the appropriate capillary can be a tedious task due to their limited viscosity range. SVM 2001 on the other hand covers the entire viscosity, density, and temperature range with one single measuring cell, turning the search for the right capillaries into a thing of the past. Even the viscosity index (VI) of lubricants and in-service oils can be measured from one syringe within a single measuring cycle. Inject your sample and SVM 2001 does the rest, measuring at two different temperatures successively and automatically calculating the VI.
Eco-friendliness at an affordable price
SVM 2001 offers great value to price-conscious users, while still outperforming all competitors on the market.
Not only does SVM 2001 make viscosity measurements smart and simple, it also requires just a small volume of sample and solvent for cleaning (min. 1.5 mL), which lowers solvent and disposal costs. In contrast to glass capillary viscometers, the high-performance kinematic viscometer SVM 2001 does not require a liquid bath and cooling equipment, meaning it saves energy and space.
Great results with little effort
Installation, operation, and maintenance of SVM 2001 are incredibly easy. The factory-adjusted instrument is ready to measure immediately after start-up. Thanks to the patented motor concept, access to the measuring cell is tool-free, which enables convenient cleaning when measuring heavily contaminated samples, such as used oils. The optional magnetic particle trap removes magnetic particles from the sample, ensuring good quality measurements.
Model | SVM 2001 | SVM 3001 | SVM 4001 | SVM 3001 Cold Properties |
Patents granted | AT5160588 (B1), US10036695 (B2), CN105424556, AT516302 (B1), CN105628550 |
Temperature | +15 °C to +100 °C | -60 °C to +135 °C | +15 °C to +100°C | +15 °C to +100°C |
range | | | | |
Viscosity range | 0.2 mm²/s to 30 000 mm²/s* |
Density range | 0.6 g/cm³ to 3 g/cm³ |
Viscosity | 0.1 % |
repeatability* | | | | |
Viscosity | 0.35% |
reproducibility* | | | | |
Density | 0.0002 g/cm³ | 0.00005 g/cm³ | 0.00005 g/cm³ | 0.00005 g/cm³ |
repeatability* | | | | |
Density | 0.0005 g/cm³ | 0.0001 g/cm³ | 0.0001 g/cm³ | 0.0001 g/cm³ |
reproducibility** | | | | |
Cloud/freeze | | | | <0.5 °C / <0.5 °C |
point | | | | |
repeatability** | | | | |
Cloud/freeze | | | | <2.5 °C / <1.3 °C |
point | | | | |
reproducibility** | | | | |
Temperature | 0.005 °C (0.009 °F) |
repeatability | | | | |
Temperature | 0.03 °C from | 0.03 °C from | 0.03 °C from | 0.03 °C from |
reproducibility | 15 °C to 100 °C | 15 °C to 100 °C | 15 °C to 100 °C | 15 °C to 100 °C |
| | 0.05 °C outside | | 0.05 °C outside |
| | this range | | this range |
Test methods | ASTM D7042, ISO | ASTM D7042, ISO | ASTM D7042, ISO | ASTM D7042, ISO 23581, |
| 23581, EN 16896 | 23581, EN 16896 | 23581, EN 16896 | EN 16896 |
| | ASTM D4052, | ASTM D4052, | ASTM D2386 equivalent |
| | ISO 12185 | ISO 12185 | or better, ASTM D2500 |
| | | | equivalent or better |
Supported | Ultrafast, Fast | Ultrafast, Fast, | Ultrafast, Fast, | Ultrafast, Fast, Precise |
| and Precise | Precise | Precise and | and Ultraprecise |
precision classes | | and Ultraprecise | Ultraprecise | |
Sample volume | 1.5 mL / 5 mL | 1.5 mL / 5 mL | 2.5 mL / 6 mL | 1.5 mL / 5 mL |
min./typical | | | | |
Solvent volume | 1.5 mL / 6 mL | 1.5 mL / 6 mL | 2.5 mL / 10 mL | 2.5 mL / 6 mL |
min./typical | | | | |
Maximum sample | 30 samples | 30 samples | 24 samples | 30 samples per hour |
throughput | per hour | per hour | per hour | |
Peltier | Designed for | Designed for fast | Designed for | Designed for fast |
temperature | constant | heating/cooling | simultaneous | heating/cooling over |
control | temperature | over a wide | measurement | a wide range |
| | range | at any two diff. | |
| | | temperatures | |
| | | within the range | |
Data memory | 1000 measurement results |
HID (Human | Touchscreen |
Interface Device) | optional keyboard, mouse and 2D bar code reader |
Interfaces | 4 x USB (2.0 full speed) |
| 1 x Ethernet (100 Mbit) |
| 1 X CAN bus |
| 1 x RS-232; 1 x VGA |
Power supply | AC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max |
Ambient | 15 °C to 35 °C (59 °F to 95 °F), max. 80% r.h. non-condensing |
conditions | |
Net weight/ | 15.9 kg/20.5 kg | 17.6 kg/22.2 kg | 17.8 kg/22.4 kg | 18 kg/22.2 kg |
shipping weight | | | | |
Dimensions | 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) |
(W x D x H) | |
Compliance | CE mark | CE mark | CE mark | CE mark |
| EMC directive EN 61326-1 |
| LV directive EN 61010-1 |
| RoHS |
Included in | Kinematic | Automatic VI | Simultaneous | Cloud point |
standard delivery | viscosity | determination | kinematic | Freezing point |
| Dynamic | API calculations | viscosity and | Temperature @ 12 |
| viscosity | Temperature | density at any | mm²/s (Kinematic |
| Density | scan | two different | Viscosity Borderline |
| | Time scan | temperatures in | Temperature: KVBT) |
| | FillingCheck™ | the range | Standard above |
| | Kinematic | Automatic VI | freeze point (SFP) |
| | viscosity | determination | Automatic VI |
| | Dynamic | API calculations | determination |
| | viscosity | Temperature | API calculations |
| | Density | scan | Temperature scan |
| | | Time scan | Time scan |
| | | FillingCheck™ | FillingCheck™ |
| | | Kinematic | Kinematic viscosity |
| | | viscosity | Dynamic viscosity |
| | | Dynamic | Density |
| | | viscosity | |
| | | Density | |
Options | Automatic VI | Modularity with | Modularity with | Sample changer, |
| determination | Abbemat | Abbemat | non-heated |
| Sample changer, | refractometers | refractometers | Counter-cooling |
| heated | Chemical | Sample changer, | |
| Sample changer, | upgrade kit | heated | |
| non-heated | Sample changer, | Sample changer, | |
| | heated | non-heated | |
| | Sample changer, | | |
| | non-heated | | |
| | Counter-cooling | | |
*Viscosity range with chemical upgrade kit from 1 to 10 000 mPa·s |
**Attested at the points of the works adjustment or at calibration correction points, |
not including the uncertainty of the standards. |
Valid for ideal measuring and sample conditions within the works adjustment range. |
SVM (EM13411996), Stabinger Viscometer (WO1232458, EM12708863), FillingCheck (EM006834725) |
| | | | |
To get information about: «Kinematic viscometer: SVM » contact us by phone (044) 229 15 31 or fill in the form.