• Condensation-free experiments under rel. humidity and temperature
• Overall temperature range from -180 °C to +400 °C; Controlled relative humidity studies from 10 °C to 80 °C
• Easy changeover from low-/high-temperature experiments to humidity measurements without opening the chamber
CHC plus+ is a unique combination of the multi-purpose CHC Cryo & Humidity Chamber and an advanced humidity (RH) generator for the analysis of humidity-dependent and/or temperature-dependent structural changes in materials using X-ray diffraction. Investigations into pharmaceuticals, fine chemicals, clays or zeolites can be carried out in humid gas, air, inert gas or vacuum. Controlled humidity is possible for sample temperatures from 10 °C to 80 °C.Due to its versatility, the new combined CHC plus+ setup opens new dimensions in analysis for materials science and is a true "workhorse" for the pharmaceutical industry.
Defined temperature and environmental conditions
Computer-controlled temperature control unit and RH generator
Fast, accurate, and stable temperature control
Well-defined, uniform humidity conditions around the sample
Gas humidifier on the CHC lid and temperature-controlled chamber housing prevent any condensation problems
Reliable monitoring of the sample environment
Precise Pt100 temperature sensor for temperature measurement and control
Calibrated RH sensor close to the sample and new humidity generator guarantee accurate humidity control
Sample temperature range from –180 °C to +400 °C with liquid nitrogen cooling, and from –5 °C to +400 °C with compressed air cooling
Optimal for analyzing organic materials
Easy changeover from low/high-temperature experiments to humidity measurements without opening the chamber
Integrated beam knife for measurement at low 2Θ angles
Easy mounting and exchange of samples without realignment
Sample holders with various depths and zero background option
| |
Model | CHC plus⁺ |
| |
Operating temperature with compressed air cooling | Vacuum (10-2 mbar): -5 °C to 400 °C; air ; inert gas: -5 °C to 300 °C; |
humid gas: 10 °C to 80 °C |
Operating temperature with liquid nitrogen cooling | Vacuum: -180 °C to 400 °C |
Air, dry nitrogen: -120 °C to 300 °C |
Relative humidity range | 5 to 95 % RH at 10 °C to 60 °C |
5 to 70% RH at 80 °C |
Temperature measurement | Pt 100 |
Atmospheres | (Humid) air/nitrogen, inert gas, vacuum (10-2 mbar) |
Scan range | 0 to 164° 2θ |
Max. operating pressure | 0.2 bar above atmospheric pressure |
Sample holder surface | Copper, chromed |
Sample cavity area | 10 x 14 mm |
X-ray geometry | Reflection |
| |
| |
Платформи для рентгенівської дифракції.pdf
To get information about: «CHC plus⁺» contact us by phone (044) 229 15 31 or fill in the form.