All-in-one purification system
The PrepChrom C-700 offers an interactive user interface, and simultaneously enables an easy and fast purification process. The high performance preparative chromatography system allows running both flash and preparative HPLC separations.
Accelerated purification
• Flash chromatography separation and subsequent preparative HPLC purification of all relevant fractions on the same system
• Save time when optimizing the separation of complex samples using up to 4 solvents
• Detect all compounds at once with DAD and optional ELSD
• Fast separations on high efficiency columns
High performance
• Full separation optimization capabilities with quaternary gradient functionality (HPLC pump technology)
• High efficiency preparative HPLC columns (10 or 15 µm) can be run at a pressure of up to 100 bar (1450 psi)
• Optimal fraction purity resulting from a highly selective separation
Easy to use
• Perform prep HPLC as easily as flash chromatography
• Intuitive graphical user interface designed for purification applications
• Easy connection of flash cartridges, glass columns or preparative HPLC columns
• Multilanguage user interface with touch screen
| |
Model | PrepChrom C-700 |
| |
Pressure range | up to 100 bar (1450 psi) |
Flow rate range | 5 - 250 mL/min |
Flow rate accuracy at 10 - 250 mL/min | < 5 % |
Flow rate repeatability at 10 - 250 mL/min | < 1 % |
Gradient step tolerance at 80 mL/min, 80 bar (1160 psi) | < 3.5 % |
Interfaces | |
| 9 x RS-232 (1 female, 8 male) |
| 1 x RJ45 |
| 1 x solvent level sensor port |
| 1 x analog port |
| 2 x control signal ports |
Environmental conditions | |
Temperature | 5 - 40 °C for indoor use only |
Altitude | up to 2000 m |
Humidity | Maximum relative humidity 80 % for temperature up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C |
Pump | |
Gradient | Quaternary gradient |
Air inlet | Drying of flash cartridges |
Mixing chamber | Static with adjustable volume |
Protective elements | Pressure sensor (shutdown based on selected column and at 100 bar) |
| Leak sensor |
Material in contact with solvent | PEEK, saphire, ceramic, FEP, ruby |
Control signals | Start - In, Stop - In, Start - Out, Stop - Out, solvent level sensor |
Interface | 1 x RS-232 female |
| |
Detector | |
Wavelength range | 200 - 600 nm |
Accuracy of adjustment | ± 1 nm |
Reproducibility | ± 0.5 nm |
Flow cell path length | 0.3 mm |
Noise level at test cell | ± 5 x 10-5 AU at 254 nm, TC 0.75 s |
Drift at test cell (254 nm after 1 h) | 1 x 10-3 AU/h |
Time constant (T90) | 1 s |
Light source | Deuterium discharge lamp |
Maximum flow rate | 500 mL/min |
Maximum pressure at the cell | 20 bar / 290 psi |
Output for integrator | 1 V/AU (in digital form only |
Interface | 1 x RS-232 male |
| |
| |
Dimensions (W × H × D) | 355 x 890 x 495 mm |
Weight | 53 kg |
Connection voltage | 110 - 120 V / 220 - 240 V ± 10 % |
Fuse 220 - 240 V | |
| 1 x TT2.5A L 250V |
| 4 x TT1.25A L250V |
Frequency | 50 / 60 Hz |
Power consumption | max. 350 W |
Degree of protection | IP20 |
Overvoltage category | II |
Pollution degree | 2 |
| |
Technical data sheet in English
PrepChrom C-700
Technical data sheet
Брошюра (по-русски)
Высокопроизводительная система препаративной хроматографии позволяет выполнять как флэш-хроматографию, так и препаративное разделение HPLC в единой системе.
Preparative_Chromatography_Solution_brochure_ru_A_01.pdf
To get information about: «PrepChrom C-700» contact us by phone (044) 229 15 31 or fill in the form.