• Determination of turbidity in a variety of fluids
• Compliance with acknowledged standards such as MEBAK and EBC
• Modular solution to fit with Anton Paar’s measurement solutions
• Active temperature control for highly precise results
A solution for the measurement of turbidity in liquids, the HazeQC ME turbidity measuring module, is provided by Anton Paar as part of a modular measuring system. The approved ratio method with measurement at three angles (transmission 0°, scattered light at 25° and 90°) is used to prevent the influence of particle size on the turbidity value. The measurement is carried out at a wavelength of 650 nm ±30 nm (MEBAK- and EBC-compliant) in a cell with adjustable constant temperature. This turbidity measuring module expands Anton Paar's product portfolio and adds a further important parameter for analyzing liquid samples - providing the same high quality expected of Anton Paar products.
Accurate and traceable turbidity measurement
• Three-angle turbidity measurement (transmission 0°, scattered light at 25° and 90°) at 650 nm according to MEBAK and EBC
• Approved ratio method eliminates the influence of particle size on the turbidity value
• Highly accurate Peltier-thermostatted cell
Combinations for up to 7 parameters possible
• Up to 7 parameters in one measuring cycle if used in combination with PBA-B (density, alcohol, beer color, pH, CO2, O2, turbidity)
• Combination with all Generation M systems, with Alcolyzer Plus Beer, with Alcolyzer Plus Spirits or with the Beer Analyzing System (Alcolyzer Plus Beer, density meter, sample changer)
• All measurements directly out of the bottle or can, no degassing required if using a PFD Filling Device
Model | HazeQC ME |
Measuring range |
Turbidity | 0 EBC to 100 EBC (0 NTU to 400 NTU) |
Temperature | -5 °C to 40 °C (temperatures below 15 °C require an external cooling) |
Repeatability s.d. |
Turbidity | 0.02 EBC (0.08 NTU) |
Temperature | 0.01 °C |
Additional information |
Measurement principle | Three-angle stray light and absorbance measurement (0°, 25° and 90°), ratio method for the reduction of interferences |
Wavelength | 650 nm |
Minimum sample volume | approx. 3 mL |
Measuring time per sample | 3 to 4 minutes (incl. filling) |
Interfaces | 2 x CAN |
Wetted parts | EPDM, FEP, glass, PEEK, PTFE, PU, stainless steel, Tygon |
Dimensions | 380 mm x 160 mm x 190 mm (15 in x 6.3 in x 7.5 in) |
(L x W x H) | |
Weight | 5.3 kg (11,7 lbs) |
External thermostat | Flow rate: 0.4 L/min to 0.7 L/min |
(optional) | Maximum pressure: 0.5 bar (7.3 psi) |
| Temperature of the cooling medium: 15 °C to 25 °C |
| |
Currently there is nothing to download
To get information about: «HazeQC ME» contact us by phone (044) 229 15 31 or fill in the form.