ru-RUuk-UAen-GB

Diana 700

Full description

Atmospheric Distillation Analyzer:


• High-precision distillation unit for fuels and solvents
• Indestructible vapor temperature sensor that lasts forever
• Accelerated cooling between measurements means you save time and can start the next measurement right away
• Guides you step-by-step through the setup for distillation

Diana 700 is the ideal solution for automatically performing high-precision distillation range analysis at atmospheric pressure. Typical samples to be characterized include petrochemical products, aromatic hydrocarbons as well as other volatile organic liquids.

The combination of premium technology and distinguished features leads to unrivaled ease of use, high efficiency, and safe operation.

Smart operator assistance
Diana 700 automates manual handling steps during the measurement setup to provide maximum support. Additionally, for untrained users the innovative user interface employs illustrations as a step-by-step guide through the procedure that is necessary to start a distillation. For experienced users, the advanced mode just shows the state of each component of the instrument and enables a fast start of the distillation. The intelligent condition monitoring system controls all steps and Diana 700 only allows you to start a measurement if all steps have been completed correctly. This helps to avoid having to repeat a measurement due to an incorrect setup or non-compliance with the standard.

Convenient handling: Mobile multi-plug
For a perfect operator experience and to increase the usability of the instrument, the vapor temperature sensor was combined with the flask holder. The resulting multi-plug was developed by considering valuable customer feedback. With just one hand and within seconds it is possible to install the distillation flask (125 mL or 200 mL) in the correct position.
The integrated data memory stores the calibration data of the temperature sensor which is automatically applied when the sensor is mounted to the instrument.

Safety first: Automatic heater and shield lift
As soon as the distillation flask has been installed the heater and the protection shield move up fully automatically. The correct flask and flask support board are identified by the instrument and only if the correct type is installed can the distillation be started.
For a maximum level of safety, the automatic shield lift surrounds the flask, reducing the risk of touching any hot parts while a measurement is running. After finishing the test, the heater moves down to accelerate the cooling of the flask. This means you save time and can start your next measurement right away.

Easy to operate and efficient: The receiving chamber
You can operate the receiving chamber of Diana 700 smoothly to access the receiving cylinder. Thanks to the tight jacketing of the cylinder, the chamber guarantees an excellent stability of the sample and cylinder temperature.
Using the highly efficient Peltier technology, Diana 700 enables a fast switch between different ASTM D86 distillation groups and reaches the required temperatures in less than five minutes.
A unique cold trap avoids condensation caused by high humidity and reduces evaporation losses of volatile organic compounds (VOC) at the same time.

Highly accurate volume detector
The volume detection of the atmospheric distillation unit Diana 700 makes use of the high accuracy of contact imaging sensor technology (CIS) to achieve a precise determination of the sample volume. This solid state technology is able to continuously follow the liquid level in the cylinder. Additionally, the volume is measured by the instrument before the test starts and corrected to 100 % volume, if necessary.
Product specification
Model Diana 700
Tempering system
Liquid-free Peltier cooling technology
Temperature range up to 450°C vapor temperature
  0°C to 80°C condenser temperature
  0°C to 60°C chamber temperature
Measuring system Pt100 vapor temperature sensor, class A
  Volume detection by contact imaging sensor technology
Safety Automated fire-extinguishing system with detection if gas is connected
  Automatic self-check at instrument start
  Intelligent condition monitoring system to avoid incorrect setups
  Reduced volatile organic compound (VOC) emission
Interfaces USB, LAN, HDMI
Display 10" TFT, PCAP touchscreen
Gas supply N2 or CO2 (6 bar to 12 bar)
Power supply 90 V to 240 V, 50 Hz/60 Hz, 900 W
Dimensions 406 mm x 525 mm x 645 mm (W x D x H)
Weight approx. 40 kg
Other special functions Mobile multi-plug with integrated vapor temperature sensor 
  for wireless flask handling
  Built-in sensor for ambient temperature, pressure, and humidity
Downloads
Brochure_Diana700.pdf
Multimedia
Перегонка при атмосферном давлении ДИАНА 700
Обзор аппарата для проведения перегонки нефтепродуктов при атмосферном давлении DIANA (ДИАНА) 700



To get information about: «Diana 700» contact us by phone (044) 229 15 31 or fill in the form.
E-mail
Phone
First name
Family name
Country
Company name
Request
Input symbols from the picture