ru-RUuk-UAen-GB

Analyzing system: Diet Beverage

Full description
• Determines the %Diet concentration in colored, uncolored, and turbid diet drinks
• Ready to analyze regular soft drinks next to diet drinks
• Results in 3 to 5 minutes
• Optional pH measurement
Anton Paar’s Diet Beverage Analyzing System is the ideal solution for your diet drink. The system determines the %Diet concentration in diluted diet syrups and degassed final beverages. Combine the master instrument with Anton Paar’s diet module for your daily beverage quality control in the production process. For automated filling and/or cleaning, the Diet Beverage Analyzing System can be upgraded with different types of sample changers. Benefit from a unique solution for your individual requirements.

Analyze all kinds of diet syrups and degassed beverages
Simply combine DMA 4500 M with a DietQC ME for a detailed diet beverage analysis to get the full range of vital parameters. Your options are endless: You can also choose the most accurate density meter in the world, DMA 5000 M, to measure turbid samples, DietQC ME with the option for uncolored drinks, or a module for pH determination. The Diet Beverage Analyzing System is also applicable for sugared soft drinks.
With only one measuring system, you can cover your whole soft drink portfolio.

Be ready for future requirements in beverage quality control
With the Diet Beverage Analyzing System, you can easily automate your measurements. Anton Paar’s sample changers free you from spending too much time on standard tasks: Choose Xsample 320 for automated filling of a single sample and Xsample 520 to fill up to 96 samples in a row. Xsample 330 not only fills the sample automatically, it also performs a cleaning routine right after the measurement to keep the instrument measuring accurately over a long time.
In case you want to get results for CO2 in your final product, Anton Paar also has the right solution for you: Simply upgrade to the Packaged Beverage Analyzer for soft drinks.

The most accurate results for the analysis of diet beverages
Make the most out of your soft drinks and reach maximum efficiency in your production. When measuring diet beverages, DietQC ME with integrated absorption measurement guarantees reproducible results with a minimum of reference measurements. The Diet Beverage Analyzing System with an integrated DMA 5000 M provides highly accurate density values, based on the patented Pulsed Excitation Method, and is the high-end solution for turbid samples.

Maximum level of usability
DietQC ME can be connected to the master instrument (either DMA 4500 M, DMA 5000 M, or Soft Drink Analyzer M, depending on your requirements) which has a number of intelligent features to make your daily life in the lab easier: FillingCheck™ confirms the bubble-free filling of the density and sound velocity measuring cell. If there is a problem with the filling, FillingCheck™ generates and records filling warnings. The state-of-the-art 10.4” PCAP touchscreen is robust yet sensitive. Measurement reports can be printed out in a standardized layout or the data can be transferred to your individual data system for full traceability of the measurements.
Product specification
Model Analizing system Diet Beverage
 
 Measuring range Repeatability s.d.
Density(1) 0 g/cm³ to 3 g/cm³ DMA 5000 M/ SDA M: 0.000001 g/cm³
Sound velocity 1000 m/s to 2000 m/s 0.1 m/s
Concentration sugar 0 °Brix to 15 °Brix <0.01 °Brix
Concentration sugar fresh/  0 °Brix to 15 °Brix 0.02 °Brix
inverted    
Degree of inversion 0 % to 100 % 0,01
Diet concentration 0 % to 200 % or Colored diet drinks: 0.2 %
For typical diet beverage  0 mL to 100 mL NaOH or Uncolored diet drinks 
compositions    (via UV measurement): 0.4%
  0 g/L to 100 g/L TA Uncolored or turbid diet drinks 
    (via density measurement): 0.4 %
pH pH 0 to pH 14 0.02 (in the range pH 3 to pH 7)
(1) according to ISO 5725    
     
Measuring time 3 to 5 minutes
Sample temperature DMA M as master: 4 °C to 25 °C (39 °F to 77 °F)
  SDA M as master: 15 °C to 25 °C (59 °F to 77 °F)
Sample volume per  30 mL (approx. 20 mL per additional measuring module)
measurement    
Dimensions DMA M/SDA M: 495 mm x 330 mm x 230 mm (19.5 in x 13 in x 9.1 in)
  Xsample 520: 532 mm x 347 mm x 360 mm (20.9 in x 13.7 in x 14.2 in)
Voltage AC 100 to 240 V, 50/60 Hz
Power consumption 190 VA (incl. external measuring modules)
Power inlet According to IEC/EN 60320-1/C14, protection class I
Fuses Glass tube fuses 5 mm x 20 mm; IEC60127-2; AC 250 V; T 5 AH
Environmental conditions  Indoor use only
(EN 61010)    
Ambient temperature 15 °C to 35 °C (59 °F to 95 °F)
Air humidity 10 % to 90 % relative humidity, non-condensing
Pollution degree 2
Overvoltage category II
Altitude max. 3000 m (9800 ft)
Touchscreen 10.4” TFT PCAP touchscreen 640 px x 480 px
Memory 1000 measured data with/without camera pictures
Interfaces 4x USB
  Ethernet
  CAN Bus
  RS 232
  VGA
RS232 printer settings Interface: RS232; Baud rate: 9600; Parity: none; Stop bit: 1; Data bits: 8