ru-RUuk-UAen-GB

NOVAtouch series

Full description

High-throughput surface area and pore size analyzer


The NOVAtouch series are the instruments of choice for hundreds of labs globally. These rapid, high-throughput vacuum volumetric gas sorption analyzers provide quality control and research labs alike with the surface area and pore size analysis capabilities they require – and all this at an affordable price. Either two or four analysis stations with four built-in vacuum or flow degassing stations reduce the overall bench space while maximizing performance. A 21 CFR Part 11 compliant version of the software is available for pharmaceutical customers.

• Perform fully automated multi-point B.E.T. analysis in as little as eight minutes.
• Eliminate the need for helium with patented NO Void Analysis™ (NOVA) technology.
• Analyze up to 2000 data points (1000 adsorption points and 1000 desorption points).
• Prepare four samples by vacuum or flow methods simultaneously with sample analysis.
• Access degasser during analysis to start / stop degassing.
• View data “on the fly” locally on the color touchscreen.
• Eliminate cell calibration with classical helium-void-volume mode.
• Transfer data via Ethernet connection.
• Enhance performance with Windows®-compatible software.
• Verify performance with rapid calibration check.
• Dedicated Po cell and transducer for greater analysis resolution and speed.
• Meets the special needs of busy research laboratories.
Product specification
Model NOVAtouch series
General specifications
Ambient temperature range 15 °C to 40 °C
Relative humidity <80 %
Dimensions (W x D x H) 61.6 cm x 49.2 cm x 82.9 cm
Weight 43 kg 
Analysis specifications
Analysis stations 2 (NOVAtouch LX2) or 4 (NOVAtouch LX4)
Adsorbates Nitrogen, argon, carbon dioxide and 
  any other inert gas
Surface area range 0.01 m²/g to no known upper limit
Pore volume (STP) <0.0001 cc/g
Total pore volume At user selectable P/P0
Pore size range 3.5 Å* to 5000 Å (0.35 nm* to 500 nm)
Reproducibility <2 % (typical)
Maximum analysis time >40 hours (with liquid nitrogen)
Coolant level control CLS coolant sensor
Number of degassing stations Four (vacuum and flow capable)
*3.5 Å to 20 Å range only covered using CO₂ on carbonaceous samples
Pressure specifications
Pressure transducer accuracy >±0.01 % of span
Pressure range 0 MPa to 0.13 MPa (0 torr to 1000 torr)
Pressure resolution 0.00006 torr (60 micro-torr)
P₀ measurement Periodic using dedicated P₀ transducer
Downloads
NOVATouch_Brochure.pdf
Brochure_ParticleCharacterization.pdf
Multimedia
Корпорація Quantachrome Instruments


Як вимірюється площа поверхні та розмір пір


Наступне покоління аналізаторів NOVA Quantachrome.



To get information about: «NOVAtouch series» contact us by phone (044) 229 15 31 or fill in the form.
E-mail
Phone
First name
Family name
Country
Company name
Request
Input symbols from the picture