High-throughput surface area and pore size analyzer
The NOVAtouch series are the instruments of choice for hundreds of labs globally. These rapid, high-throughput vacuum volumetric gas sorption analyzers provide quality control and research labs alike with the surface area and pore size analysis capabilities they require – and all this at an affordable price. Either two or four analysis stations with four built-in vacuum or flow degassing stations reduce the overall bench space while maximizing performance. A 21 CFR Part 11 compliant version of the software is available for pharmaceutical customers.
• Perform fully automated multi-point B.E.T. analysis in as little as eight minutes.
• Eliminate the need for helium with patented NO Void Analysis™ (NOVA) technology.
• Analyze up to 2000 data points (1000 adsorption points and 1000 desorption points).
• Prepare four samples by vacuum or flow methods simultaneously with sample analysis.
• Access degasser during analysis to start / stop degassing.
• View data “on the fly” locally on the color touchscreen.
• Eliminate cell calibration with classical helium-void-volume mode.
• Transfer data via Ethernet connection.
• Enhance performance with Windows®-compatible software.
• Verify performance with rapid calibration check.
• Dedicated Po cell and transducer for greater analysis resolution and speed.
• Meets the special needs of busy research laboratories.
Model | NOVAtouch series |
General specifications |
Ambient temperature range | 15 °C to 40 °C |
Relative humidity | <80 % |
Dimensions (W x D x H) | 61.6 cm x 49.2 cm x 82.9 cm |
Weight | 43 kg |
Analysis specifications |
Analysis stations | 2 (NOVAtouch LX2) or 4 (NOVAtouch LX4) |
Adsorbates | Nitrogen, argon, carbon dioxide and |
| any other inert gas |
Surface area range | 0.01 m²/g to no known upper limit |
Pore volume (STP) | <0.0001 cc/g |
Total pore volume | At user selectable P/P0 |
Pore size range | 3.5 Å* to 5000 Å (0.35 nm* to 500 nm) |
Reproducibility | <2 % (typical) |
Maximum analysis time | >40 hours (with liquid nitrogen) |
Coolant level control | CLS coolant sensor |
Number of degassing stations | Four (vacuum and flow capable) |
*3.5 Å to 20 Å range only covered using CO₂ on carbonaceous samples |
Pressure specifications |
Pressure transducer accuracy | >±0.01 % of span |
Pressure range | 0 MPa to 0.13 MPa (0 torr to 1000 torr) |
Pressure resolution | 0.00006 torr (60 micro-torr) |
P₀ measurement | Periodic using dedicated P₀ transducer |
| |