EVOLVE Manual Pipette

Full description
Unlike traditional pipettes which utilize a single rotating plunger to set volumes, EVOLVE features one dial for setting each of three volume digits. Simply depress and twist the plunger to release spring tension from the volume dials. This allows users to freely adjust all dials in either direction. Once set, twist and return the plunger to the up position.

Volumes set on traditional manual pipettes can often change while pipetting due to unintentional plunger turns. The EVOLVE Quick Set Dial design prevents inadvertent volume drift due to plunger movements while pipetting.
Traditional pipettes make frequent adjustment of volumes tedious, especially when switching from lower to higher volumes. Еhe EVOLVE manual pipette reduces repetitive stress injuries and allows users to set volumes in a fraction of the time it takes with a traditional manual pipette.

GripTips

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which distorts the shape of the pipette tip rim. The distorted pipette tip rim immediately starts moving back to its original shape, away from the tip cone. This can cause leaking, unaligned tips and even pipette tips that completely fall off the pipette!
This will never happen with any EVOLVE pipette / GripTip combination. GripTips effortlessly snap onto the tip fittings and are easily ejected. Also, Grip-Tips feature a high lateral resistance once attached to EVOLVE pipettes. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed.

Customize the Force

Two interchangeable plunger springs allow users to customize the force needed to depress the plunger to their preference. Changing the spring is completed in seconds. The controlled plunger spring option allows users to slow the aspiration and dispense speeds resulting in improved pipetting technique and results.
Product specification
Specifications and Ordering Information
CHANNEL PART No. VOLUME RANGE, µl VOLUME INCREMENTS, µl TEST VOLUME, µl ACCURACY, ±% COEFFICIENT OF VARIATION, ≤%
1 3011 0.2-2.0 0.001 0 12.00 6.00
        1 3.00 1.60
        2 1.80 1.00
3012 1-10 0.01 1 5.00 3.00
5 1.50 0.80
10 1.20 0.50
  3013 2-20 0.01 2 7.00 2.00
        10 1.60 0.50
        20 1.20 0.35
3015 10-100 0.1 10 3.50 1.00
50 1.00 0.35
100 0.80 0.20
  3016 20-200 0.1 20 2.50 1.00
        100 1.00 0.30
        200 0.50 0.18
3018 100-1000 1 100 3.00 0.60
500 1.00 0.30
1000 0.80 0.20
  3019 500-5000 5 500 3.00 0.70
        2500 1.20 0.30
        5000 0.60 0.18
8 3022 1-10 0.01 1 12.00 7.00
5 4.00 3.00
10 2.00 1.20
  3024 5-50 0.05 5 5.00 2.00
        25 2.00 1.00
        50 1.20 0.50
3025 10-100 0.5 10 5.00 2.00
50 2.00 0.80
100 1.20 0.50
  3026 20-200 0.5 20 5.00 1.30
        100 2.00 0.50
        200 1.20 0.40
12 3032 1-10 0.01 1 12.00 7.00
5 4.00 3.00
10 2.00 1.20
  3034 5-50 0.05 5 5.00 2.00
        25 2.00 1.00
        50 1.20 0.50
3035 10-100 0.5 10 5.00 2.00
50 2.00 0.80
100 1.20 0.50
  3036 20-200 0.5 20 5.00 1.30
        100 2.00 0.50
        200 1.20 0.40
The multichannel specifications represent the performance of all channels of a pipette
Downloads
Currently there is nothing to download
Multimedia
INTEGRA EVOLVE Manual Pipettes Funny Explainer Video
Now Mason can set the volumes more than 10 times faster to spent more time with Marie.