Cora 5001 Direct
• Time-saving: the autofocus finds the spot with the best Raman signal within seconds
• Laser Class 1 for the safest use
• Tailored accessories for liquid and solid samples, pills, foils, microscope slides, and very small samples
Model: Cora 5001 Fiber
• Flexible probe for measurements outside the instrument
• Safe triggering at the point of measurement for easy one-handed analysis
• Tailored accessories for liquid and solid samples
Cora 5001 is a Raman analyzer for the quick and reliable identification of substances based on their unique chemical fingerprint. Choose the Fiber model for flexible analysis outside the instrument via a probe or the Direct model which analyzes samples in a closed compartment and has a laser Class 1 for the safest use. The guided analysis procedure means Cora 5001 is suitable for operation by personnel with minimum training. The small footprint and battery option make these benchtop Raman instruments versatile tools for analytical tasks in-house or in the field.
Easy and safe – excellent user guidance and laser Class 1
The handling of the Cora 5001 Raman spectrometers can be learned within minutes, even by inexperienced users. Your new employees or students are able to perform Raman spectroscopy measurements within a very short time. In contrast to many handheld instruments, the Cora 5001 Direct Raman instruments provide extra safety due to specified laser Class 1. The laser can only be activated if the measuring chamber is closed and therefore poses no threat to people working in close vicinity to the device.
No sample preparation – accessories for every sample type
Regardless of whether the sample is a solid, liquid, or powder, Cora 5001 has the appropriate sample holder for it. You can use vials with various diameters and shapes (round, square, rectangular) or directly analyze solid samples (pills, sample carriers, etc.). Equipped with magnets, the holders are quickly and precisely positioned in the instrument, allowing for immediate sample measurement without refocusing
Versatility in a nutshell – one instrument, many samples
Do you work with fluorescing substances or many different samples? To cover the widest range of samples and account for possible fluorescence the “dual-core Raman” option gives you two different wavelengths in one instrument. Each Raman core is a fully equipped independent optical spectrometer system. Hop from one wavelength to the other at the click of a button without alignment or recalibration and analyze the whole range of substances.
Maximum robustness – no moving parts
The Cora 5001 series of portable Raman spectrometers is unaffected by shocks and vibrations and ready to work with you in the warehouse or in a busy laboratory. There are no moving parts and all sensitive optical components are protected within the optical bench which is a solid block of machined aluminum.
Autofocus – gets the strongest signal for reproducible results
Manual focusing on thin or opaque samples with a weak Raman signal can be tricky. The Cora autofocus feature finds the spot with the best Raman signal within seconds so you don’t have to worry about it. With Cora 5001 you scan, it matches, and the task is done.
Model | Cora 5001 |
Single-wavelength |
Optical specifications |
Excitation wavelength | 532 nm | 785 nm | 1064 nm |
Spectral range | 200 cm-1 | 100 cm-1 | 100 cm-1 |
| to 3500 cm-1 | to 2300 cm-1 | to 2300 cm-1 |
Resolution (according | 9 cm-1 to 12 cm-1 | 6 cm-1 to 9 cm-1 | 12 cm-1 to 17 cm-1 |
to ASTM E2529) | | | |
Laser power | 50 mW | 0 mW to 450 mW, | 0 mW to 450 mW, |
| | adjustable | adjustable |
Spectrograph | f/2; Transmission Volume Phase Grating (VPG) |
Integration time | 0.005 s to 600 s | 0.005 s to 600 s | 0.001 s to 20 s |
Wavelength calibration | Automatic via software |
Detector array | 2048 px CCD | 2048 px CCD | 256 px InGaAs |
Laser class | 1 for Direct model |
| 3B for Fiber model | | |
| Dual-wavelength | |
Optical specifications |
Excitation wavelength | 532 nm and 785 nm |
Spectral range | 200 cm-1 to 3500 cm-1 for 532 nm |
| 100 cm-1 to 2300 cm-1 for 785 nm and 1064 nm |
Resolution | 9 cm-1 to 12 cm-1 for 532 nm |
(according | 6 cm-1 to 9 cm-1 for 785 nm |
to ASTM E2529) | 12 cm-1 to 17 cm-1 for 1064 nm |
Laser power | 50 mW for 532 nm |
| 0 mW to 450 mW for 785 nm and 1064 nm |
Spectrograph | f/2; Transmission Volume Phase Grating (VPG) |
Integration time | 0.005 s to 600 s for 532 nm and 785 nm |
| 0.001 s to 20 s for 1064 nm |
Wavelength calibration | Automatic via software |
Detector array | 2048 px CCD for 532 nm and 785 nm |
| 256 px InGaAs for 1064 nm |
Laser class | 1 for Direct model |
| 3B for Fiber model |
Physical specifications |
Dimensions | 355 mm x 384 mm x 168 mm (D x W x H) |
Weight | 9.8 kg |
Operating range | 10 °C to 35 °C (non-condensing) |
Fiber probe dimensions | Cable length: 1.50 m |
Battery (optional) | Lithium-ion |
Battery run time | >1.5 h |
Power supply input | Line power supply input: 115/230 V AC, 50/60 Hz |
| Car power adapter input: 9 V to 32 V DC |
Power consumption | In line power supply input: max. 100 VA |
| DC input: typical 30 VA (60 VA when optional battery |
| is charged) |
Additional specifications |
Display | 10-inch touchscreen |
Data ports | 4 x USB 2.0, 1 x Ethernet, 1 x CAN out and 1 x USB to PC |
Data export formats | .csv, .txt, .png, .spc, .aps, .pdf |
Internal storage | 8 GB |
Wireless connectivity | WiFi stick (optional) |
Spectral libraries | Factory library, user-built, third-party options |
Security | User roles with customizable permissions, user |
| password logins |
| | | |