deneme bonusu yatırımsız şartsız deneme bonusu deneme bonusu veren siteler
Bahis siteleri
hd porno
Deneme bonusu veren siteler Deneme bonusu veren siteler Deneme bonusu veren siteler Deneme bonusu veren siteler
SMS Receive Online
deneme bonusu veren siteler
ladesbet giriş casino siteleri süperbetin giriş casino siteleri ladesbet giriş
deneme bonusu bonus veren siteler
deneme bonusu veren siteler
casino siteleri
alanya escort gaziantep escort gaziantep escort gaziantep escort mersin escort
anadolu escort bostancı escort ataşehir escort
streameast
casino siteleri
casino siteleri
deneme bonusu veren siteler
streameast
betmarino
betmarino giriş betmarino giriş betmarino giriş betmarino giriş
betmarino
deneme bonusu veren siteler
crackstreams
deneme bonusu veren siteler
deneme bonusu veren siteler
streameast
ru-RUuk-UAen-GB

Chromatogram Evaluation

Description
Electronic image acquisition
For electronic image acquisition the camera – like the human eye – captures polychromatic visible light. Under white light illumination it is the light reflected from the layer background. Under long-wavelength UV light (366 nm) it is the light emitted by fluorescent substances. When short-wavelength UV light (254 nm) is used, substances absorbing UV 254 nm appear as dark zones, provided the layer contains a fluorescence indicator (fluorescence quenching). The TLC Visualizer 2 is CAMAG’s imaging and documentation system operated with visionCATS. visionCATS enables an image-based evaluation of chromatograms for quantitative evaluation. The strength of the electronic image acquisition is the overview of the complete chromatogram.


 Illumination-mode-white-lig  Illumination-mode-UV-254 Illumination-mode-UV-366






1- Chromatogram under white light; 2- Chromatogram under UV 254 nm; 3- Chromatogram under UV -366  nm

Scanning densitometry
In classical scanning densitometry the tracks of the chromatogram are scanned with monochromatic light in the form of a slit selectable in length and width. The spectral range of the CAMAG TLC Scanner 4 is 190–900 nm. Reflected light is measured either in the absorbance or in the fluorescence mode. From the acquired data quantitative results are computed with high precision and spectral selectivity.
With the TLC Scanner 4 absorption spectra can be recorded. The strengths of classical densitometry as compared with image evaluation are spectral selectivity and the higher precision of quantitative determinations.
Downloads
Chromatogram Evaluation.pdf