The single sample changer for a wide range of samples
The new industrial grade peristaltic pump in combination with automatic cleaning makes Xsample 330 perfectly suitable for measuring single low-viscosity samples with widely different properties in direct succession. Once measured, the sample is drained or recovered and the system is automatically cleaned with up to two cleaning agents. A drying step is performed by the operator to perfectly prepare the measurement cell(s) for the next sample.
Automatic cleaning
• Automatic rinsing and drying after each sample for perfect preparation of the system
• Up to two different cleaning agents can be used in any order for an individual cleaning procedure.
• Advanced settings for cleaning procedures to increase measuring performance
For a wide range of samples
• Filling with peristaltic pump covers a wide range of different sample viscosities up to 3,000 m.Pas
• All wetted parts of Xsample 330 (high resistance) are made of durable materials for aggressive samples, such as phosphoric acid or trichloroacetic acid
• Adjustable filling modes for different types of samples enable perfect measuring results
Highly efficient sample handling and easy operation
• Depending on the system size, only a minimum amount of sample volume is needed to perform a measurement
• Easy operation by an integrated user interface on the master instrument
• Straightforward measurements of different sample viscosities due to a sensor-controlled stop of the filling procedure
• Automatic sample recovery returns expensive or hazardous samples back to their vials
Model | Xsample™ 330 (High-resistance) |
Viscosity range | up to 3,000 mPa•s at ambient and measuring temperature№ |
Filling mode | with peristaltic pump: |
| Suction mode in one direction |
| Suction mode with pumping back and forth at the beginning |
Typical time for filling | 2 to 5 minutes |
and measuring cycle | |
Minimum sample volume | approx. 10 mL to 20 mL |
Compressed air supply | max. 2 bar (29 psi) relative |
| Class 3 according to ISO 8573-1: |
Quality of air necessary | max. particle size: 5 μm |
| max. pressure dew point: –20 °C |
| max. oil content: 1 mg/mі |
Environmental conditions | indoor use only |
(EN 61010) | |
Operating temperature | +15 to +35 °C |
Pollution degree | 2 |
Over voltage category | II |
Altitude | max. 3,000 m (9,840 ft) |
Power supply | supplied by the master instrument |
| AC power supply voltage according to technical data plate |
| at the rear of the master instrument |
| (protective grounding required) |
Dimensions LxWxH Xsample™ | 205 mm x 148 mm x 185 mm |
330Xsample™ 330 High-resistance | 205 mm x 148 mm x 205 mm |
Weight excl. master instrument | |
Xsample™ 330 | approx. 3.7 kg |
Xsample™ 330 High-resistance | approx. 3.8 kg |
№ Recommended for samples with a viscosity up to 500 mPa•s at ambient and measuring |
temperature. For samples with a viscosity higher than 500 mPa•s at ambient and |
measuring temperature, bubbles may occur during filling |
| |