The automatic Pensky-Martens closed-cup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. PMA 5 is suitable for flammability applications on both biodiesel and biodiesel-blended fuels along with distillate fuels like diesel, heating oil and kerosene. It is also commonly used for other potentially flammable liquids.
Benefits at a Glance
• Integrated fire-extinguishing system automatically controlled or manually released (requires N2 or CO2 gas)
• The patented One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter release, stirrer, igniter and detector contacts
• A multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth
• Memory for 1000 tests, 20 operators, 100 sample names
• Statistical analysis (Min, Max, Mean, Repeatability)
• Data handling via USB stick for import into MS Excel® or to LIMS
Convenient Operation
• Test initiation by pre-installed standard test methods and abitlity to customize methods by 15 user-defined programs
• Calibration protocol printable
• Menu navigation by jog shuttle system with easy turn-and-push operation and color-coded LED indication for each operation mode
5.7” color graphics display shows real-time measurement
• Password protection
Customized User Flexibility
• PC-software FPPNet (optional) for convenient remote handling and test data storage
• Stainless steel or small-volume sample cup (optional)
• Stainless steel sample temperature probe Pt100 (optional)
• Bar code scanner or keyboard (optional)
| |
Model | PMA 5 |
| |
Application range | up to 405 °C (°C/°F selectable) |
Ignition | Gas and electric (interchangeable) |
Heating | According to method or user-defined |
Stirring | According to method or user-defined |
Cooling | Built-in forced air (fan) |
Flash detection | Thermocouple |
Sample temperature | Pt100 glass probe |
Sample temperature calibration | Dynamic calibration against certified ASTM thermometer and offset capability with correction table (21 calibration points) |
Barometric pressure correction | Automatic correction |
Safety | Overheat protection, automatic shut-off, fire-extinguishing system, password |
Interfaces | 3x USB, 1x RS232, 1x LAN |
Gas supply | Test flame: 50 mbar of propane or butane |
| Fire extinguisher: 6 bar to 12 bar of nitrogen |
| or carbon dioxide |
Power supply | 115 V/230 V, 50 Hz/60 Hz, 1000 W |
Dimensions | 230 mm x 410 mm x 460 mm (W x D x H) |
Weight | 14 kg |
| |
| |