Heated sample changer: Xsample 630

Full description

The multi-sample changer with no limits for high viscosities


The Xsample 630 sample changer handles up to 36 heated sample positions for all Anton Paar master instruments. Improved heating leads to short heating periods, time savings, and increased performance. Temperatures up to 95 °C are achieved in the system. Even challenging samples can be measured according to strict ASTM standards. The robust design ensures reliable and maintenance-free operation. A removable magazine with dedicated non-heated positions saves time by facilitating sample handling and even makes a second measuring system obsolete.

Improved heating performance
• Short heating periods make the sample changer ready for measurement in no time
• Even measurement of highly sensitive samples (e.g. waxes) can be performed by using the optional heated waste hose.
• Heating temperatures up to 95 °C can be achieved and the highest temperature stability is provided
• Low power consumption resulting in energy savings is achieved by eight independent electrical heating circuits

Easy sample handling
• Safe and easy collection of hot samples is facilitated by a removable magazine with a thermal handle
• 36 heated positions allow for unattended and fully automated measurements.
• Optional non-heated positions for samples that are measurable at room temperature even make a second system obsolete.
• Low maintenance efforts due to electrical heating. No water bath that needs periodical inspection.

No cross-contamination due to the highest cleaning performance
• Inside and outside needle cleaning prevents sample cross-contamination and ensures the highest precision.
• Up to three different solvents can be used in any order to achieve optimal cleaning performance
• Optimized cleaning performance is achieved by the use of different cleaning modes in any order
• Increased uptime of the instruments can be achieved by automated cleaning procedures directly after the measurements.
Product specification
Model Heated sample changer: Xsample 630
Maximum temperature 95 °C (203 °F) at 20 °C (68 °F) ambient temperature, no cooling
Viscosity range with DMA M
Operation with internal  Up to 10,000 mPa·s at 95 °C heating and measuring 
air pump temperature
Operation with 2 bar  Up to 36,000 mPa·s at 95 °C heating and measuring
external compressed air  temperature
Viscosity range with 0.2 mPa·s to 5,000 mPa·s at 95 °C heating and measuring 
 SVM x001 temperature
Filling mode Pressure mode
  with integrated piston pump
  with air pump of the master instrument
  with compressed air
Minimum sample volume per measurement Approx. 3.5 mL with DMA M
  Approx. 5 mL with SVM X001
Number of sample vials
Magazine, heated  36 positions for 12 mL vials (only glass vials allowed!)
positions only  
Xsample heated /  32 positions heated / 24 positions unheated for 12 mL vials 
unheated positions (only glass vials allowed!)
Automatic filling Internal air pump of the master instrument or compressed 
 and drying air selectable
Compressed air supply  Max. 2.0 bar (29 psi) relative
(optional)  
Quality of air necessary Class 3 according to ISO 8573-1:
  max. particle size: 5 µm
  max. pressure dew point: -20 °C (-4 °F)
  max. oil content: 1 mg/m3
Environmental conditions  Indoor use only
Ambient temperature 15 °C to 35 °C (59 °F to 95 °F)
Air humidity 10 % to 90 % relative humidity, non-condensing
Pollution degree 2
Overvoltage category II
Altitude Max. 3,000 m (9,840 ft)
Max. temperature of  160 °C (320 °F)
heated parts in case   
of malfunction  
Power supply Power is supplied by the master instrument and the 
  Xsample heating controller