The multi-sample changer with no limits for high viscosities
The Xsample 630 sample changer handles up to 36 heated sample positions for all Anton Paar master instruments. Improved heating leads to short heating periods, time savings, and increased performance. Temperatures up to 95 °C are achieved in the system. Even challenging samples can be measured according to strict ASTM standards. The robust design ensures reliable and maintenance-free operation. A removable magazine with dedicated non-heated positions saves time by facilitating sample handling and even makes a second measuring system obsolete.
Improved heating performance
• Short heating periods make the sample changer ready for measurement in no time
• Even measurement of highly sensitive samples (e.g. waxes) can be performed by using the optional heated waste hose.
• Heating temperatures up to 95 °C can be achieved and the highest temperature stability is provided
• Low power consumption resulting in energy savings is achieved by eight independent electrical heating circuits
Easy sample handling
• Safe and easy collection of hot samples is facilitated by a removable magazine with a thermal handle
• 36 heated positions allow for unattended and fully automated measurements.
• Optional non-heated positions for samples that are measurable at room temperature even make a second system obsolete.
• Low maintenance efforts due to electrical heating. No water bath that needs periodical inspection.
No cross-contamination due to the highest cleaning performance
• Inside and outside needle cleaning prevents sample cross-contamination and ensures the highest precision.
• Up to three different solvents can be used in any order to achieve optimal cleaning performance
• Optimized cleaning performance is achieved by the use of different cleaning modes in any order
• Increased uptime of the instruments can be achieved by automated cleaning procedures directly after the measurements.
Model | Heated sample changer: Xsample 630 |
Maximum temperature | 95 °C (203 °F) at 20 °C (68 °F) ambient temperature, no cooling |
Viscosity range with DMA M |
Operation with internal | Up to 10,000 mPa·s at 95 °C heating and measuring |
air pump | temperature |
Operation with 2 bar | Up to 36,000 mPa·s at 95 °C heating and measuring |
external compressed air | temperature |
Viscosity range with | 0.2 mPa·s to 5,000 mPa·s at 95 °C heating and measuring |
SVM x001 | temperature |
Filling mode | Pressure mode |
| with integrated piston pump |
| with air pump of the master instrument |
| with compressed air |
Minimum sample volume per measurement | Approx. 3.5 mL with DMA M |
| Approx. 5 mL with SVM X001 |
Number of sample vials |
Magazine, heated | 36 positions for 12 mL vials (only glass vials allowed!) |
positions only | |
Xsample heated / | 32 positions heated / 24 positions unheated for 12 mL vials |
unheated positions | (only glass vials allowed!) |
Automatic filling | Internal air pump of the master instrument or compressed |
and drying | air selectable |
Compressed air supply | Max. 2.0 bar (29 psi) relative |
(optional) | |
Quality of air necessary | Class 3 according to ISO 8573-1: |
| max. particle size: 5 µm |
| max. pressure dew point: -20 °C (-4 °F) |
| max. oil content: 1 mg/m3 |
Environmental conditions | Indoor use only |
Ambient temperature | 15 °C to 35 °C (59 °F to 95 °F) |
Air humidity | 10 % to 90 % relative humidity, non-condensing |
Pollution degree | 2 |
Overvoltage category | II |
Altitude | Max. 3,000 m (9,840 ft) |
Max. temperature of | 160 °C (320 °F) |
heated parts in case | |
of malfunction | |
Power supply | Power is supplied by the master instrument and the |
| Xsample heating controller |
| |
All Xsamples
All Xsamples en