Economical vacuum regulation


The I-100 is an easy to use interface to regulate the vacuum conveniently. As the central interface of the economical solution “Rotavapor® Essential” it increases the efficiency of the evaporation process.

Economical
• Functional design fulfills essential needs of vacuum regulation
• Saves resources thanks to control of vacuum pump
• High longevity due to robust and durable design

Convenient
• User-friendly and intuitive handling thanks to self-explaining user interface
• Easy and accurate vacuum regulation
• Relevant information is displayed at a glance

Reliable
• High reliability due to centralized control of major process parameters
• Full process control thanks to parameter monitoring
• Proven technology for major applications
Product specification
Model Interface I-100
Dimensions(W x H x D) 160 x 105 x 120 mm
Weight 700 g
Measurement range 1400 – 1 mbar
Control range 1100 – 1 mbar
Measuring principle Capacitive, independent of gas type, 
  absolute pressure gauge / sensor 
  made from aluminum oxide-ceramic
Measuring accuracy ± 2 mbar (± 1 digit) - after calibration 
  at constant temperature
Vacuum connection GL14
Temperature compensation 0.07 mbar/K
Magnetic valve supply 24 V
Power consumption 10 W
Connection voltage 30 VDC
Frequency 50/60 Hz
Hysteresis Automatic or 1 – 500 mbar
Display Digital, monochrome, 4.0 in
Protection class IP21
Approvals CE / CSA
Input voltage 100 – 240 V
Output voltage 30 VDC
Multi-languages   en, de, fr, it, es, zh, ja, ru, pt-b.
Manual vacuum control Pressure settings and aeration
   is managed via buttons 
Vacuum regulation Adjusts and keeps pressure
of set pressure   stable within hysteresis
Timer function  To stop the process after pre-set time
Indication of values  Set and actual value of pressure
   are shown simultaneously on display 
Indication of icons Displays symbols when connected
  to pump and chiller 
Operation of Vacuum Pump V-100 Automatic On/Off-function
 Operation of Recirculating Automatic On/Off-function
Chiller F-105   
 Overpressure prevention   Automatic aeration when 
  pressure above 1400 mbar
Downloads
Брошюра по-русски
I-100 — простой в использовании интерфейс для удобного регулирования вакуума.
Technical data sheet in English
Interface I-100 Technical data sheet
Обзор методов упаривания по-русски
Обзор BUCHI специализированных решений для лабораторного упаривания как в R&D, так и для контроля качества.

To get information about: «Interface I-100» contact us by phone (044) 229 15 31 or fill in the form.
E-mail
Phone
First name
Family name
Country
Company name
Request
Input symbols from the picture