Dynamic climate chambers MK Series

Full description

  • Temperature range: -40 °C to 180 °C

  • APT.line™ preheating chamber technology

  • Programmable condensation protection for test material

  • Heated viewing window with LED interior lighting

  • BINDER APT-COM™ 3 Basic Edition communication software

  • Troubleshooting system with visual and audible alarms

  • Intuitive touchscreen controller with time-segment and real-time programming with internal data recording (Model 56)

  • Access port with silicone plug (Models 56, 115, 240), 50 mm, left

  • 2 access ports with silicone plugs (Model 720), 80 mm, left and right

  • 4 castors, two with brakes

  • Computer interface: Ethernet

  • 230 V power socket on the right-side control panel (Models 115, 240, 720)

  • Display via color LCD monitor

  • Adjustable ramp function

  • Integrated chart recorder

  • Real-time clock

  • Door heating

  • 1 stainless steel rack

  • BINDER test confirmation

  • Inner chamber made of stainless steel

  • Pt 100 temperature sensor

  • Thermal insulation using PUR foam

  • CFC-free refrigerant R-404A

  • Cooling with compressor cooling unit

  • Fin evaporator

Product specification
Model MK 56 MK 115 MK 240 MK 720
Measures
Interior volume [L] 60 115 228 734
Net weight of the unit (empty) [kg] 165 260 340 570
Permitted load [kg] 60 60 70 160
Load per rack [kg] 15 30 30 40
Internal Dimensions
Width [mm] 400 600 735 1200
Height [mm] 420 480 700 1020
Depth [mm] 348 400 443 600
Doors
Inner doors 1 - - -
Unit doors 1 1 1 1
Outer dimensions
Width net [mm] 720 980 1115 1580
Height net [mm] 1445 1725 1715 2005
Depth net [mm] 780 865 925 1140
Wall clearance back [mm] 200 210 335 250
Wall clearance sidewise [mm] 300 300 300 300
Viewing window width [mm] 288 288 508 508
Viewing window height [mm] 255 222 300 300
Environment-specific data
Sound-pressure level [dB(A)] 59 62 62 65
Fixtures
Number of shelves (std./max.) 1/4 1/4 1/6 1/11
Performance Data Temperature
Temperature range [°C] -40…180 -40…180 -40…180 -40…180
Temperature variation depending on setpoint [± K] 0.5…1.5 0.1…2 0.1…1.2 0.3…2
Temperature fluctuation depending on setpoint [± K] 0.1…0.5 0.1…0.5 0.1…0.5 0.1…0.5
Average heating-up rate according to IEC 60068-3-5 [K/min] 5.5 5.3 5 4
Cooling down time from 180 °C to -40 °C [min] 90 90 110 -
Average cooling down time according to IEC 60068-3-5 [K/min] 5.5 5 4.5 4.5
Max. heat compensation at 25 °C [W] 800 2000 2000 6500
Electrical data
Rated Voltage [V] 200…230 400 400 400
Power frequency [Hz] 50 50 50 50
Nominal power [kW] 3 4 4 7
Unit fuse [A] 16 16 16 16
Phase (Nominal voltage) [ph] 1~ 3~ 3~ 3~
All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
Downloads
Описание модели MK 56
Климатическая камера динамическая Binder Серии MK Модель 56
Описание модели MK 115
Климатическая камера динамическая Binder Серии MK Модель 115
Описание модели MK 240
Климатическая камера динамическая Binder Серии MK Модель 240
Описание модели MK 720
Климатическая камера динамическая Binder Серии MK Модель 720

To get information about: «Dynamic climate chambers MK Series» contact us by phone (044) 229 15 31 or fill in the form.
E-mail
Phone
First name
Family name
Country
Company name
Request
Input symbols from the picture